Swinging Door Operators


Number 1501 Operator Unit
(Shown without optional cover)
Operators used on openings
between 7' 0" and 8' 6" in height
require a cover. Operator not
intended for openings less than 7' 0"
in height.

Number 1501EHD Operator Unit.
(Shown without optional cover).

 

Recommended Capacities of Number 1501 Operator





Operator Size
Single Swing Door
In or Out (1 unit)
Pair of Swing Doors
In or Out (2 units)
Headroom Required


Projection
of Operation
from Door*
Inches




Seconds
Required
to Open
Doors




Approx.
Shipping
Weight
Pounds
Maximum Maximum
Operator
Mounted
on Door
Inches
Operator
Mounted
Above Door Standard -- Special
Opening
Width
Feet
Area
Square
Feet
Weight
per Door
Pounds
Opening
Width
Feet
Area
Square
Feet
Weight
per Door
Pounds
1/2 hp 8 120 600 16 240 1200 3 19" - 9" 11 7 to 8 170
1 hp 12 210 1160 24 420 2300 3 19" - 9" 11 7 to 8 195
+ 1 hp 14 245 1350 28 490 - 3 1/2 24" - - 16 13 to 14 525
* It is often possible to cut a pocket in side wall to give necessary clearance
+ EXTRA HEAVY GEAR UNIT Note: Units are rated to operator in a max. wind pressure of 8 psf.

Designed for use on either single doors or pairs of swinging doors, these operators provide reliable door control under heavy usage conditions. The Number 1501 operator is used one per door, and is available in 1/2 and 1 hp sizes for either single or three-phase current. Three-phase current is highly recommended for best all around operation.

For doors opening "in", the operators are mounted to the face of the door. For doors opening "out", they should be mounted to the lintel above the doorway. For installations with insufficient headroom, the operator can be mounted to the outside face of the door with a weather-resistant cover (optional extra).

The doors are operated by a sturdy, simple crank and connecting arm movement using the harmonic motion principle for smooth, gradual starting and stopping.

A safety friction disc clutch drives the crank arm and helps protect doors, motors and others mechanisms from damage in case other door comes in contact with an obstruction. Door travel is controlled by automatic limit switches. When the doors are in a closed position, they are automatically locked. Manual operation is provided by a pull chain emergency release.


1501 Specifications - Typical 1501 Installation - 1501XHD Specifications - Back to Door Operators - Home